ZAPL 3AM+
Download Brochure |
Download Manual
CONFIGURATION OPTIONS |
|
ZAPλ3AM240V5A4w+e/g |
3 phase, 4-wire, 240V, 5A, CT |
ZAPλ3AM110V5A3w+e/g |
3 phase, 3 wire, 110V, 5A, CT & VT |
IP communication +e |
Built in Ethernet adapter |
GSM GPRS/SMS +g |
Built in GSM modem for Zap-BS-AMR |
ELECTRICAL RATING |
||
Standards |
IEC62053-21, IEC62053-23 |
|
ZAPλ3AM240V Voltage range (P-N / P-P) |
57.7/100 – 240 /415 V |
|
ZAPλ3AM110V Voltage range (P-P) |
110 – 480 V |
|
Frequency range |
40 – 60 Hz |
|
Burden voltage circuit <0.8W, current circuit <0.05VA |
||
Operating temperatures |
-30 ºC to + 70 ºC |
|
Storage temperatures |
-45 ºC to + 85 ºC |
|
Accurancy Class 1 |
||
Protection Class 2 |
||
Supports VT and CT connections |
||
Multipule meter can be installated (4 ZAPλ per set of CTs) |
||
DISPLAY |
Instrumentation values (see instrumentation data) |
Large 8-digit with configurable decimal point & multiplier (k, M) Displays primary or secondary values |
IEC 62056-61 OBIS code display with digit height 11.9mm |
Life in excess of 15 years |
COMMUNICATIONS |
Standard IEC 62056-21 flag port 9600 bps |
Serial RS485/232 port |
IP via Ethernet (Option) |
IP via GSM-GPRS, wakeup SMS or dropped call (Option) |
INPUTS & OUTPUTS |
15 way connector for 6 verification pulse outputs, 1 Hz pulse output and RS485. A RJ45 connector for Ethernet port (option) |
Pulse output verification to IEC62053-31 standard |
6 verification pulse outputs: Active import, export energy (kWh), Reactive import, export energy (kVArh), Apparent import & export energy (kVA) |
LED outputs for active & reactive energy IEC62053-31 |
Push buttons for display and protected programming |
Voltage inputs 12V/220V for Source of supply (SoS) function trigger |
SECURITY (INSTALLATION & DATA) |
Meter requires only two phases or a phase & a neutral to function |
User access tracking: date & time and count |
Programming protection: sealed push button and password |
Factory sealed case. Sealable terminal cover by owner |
On power down a super capacitor, battery & backup battery ensures backup & continued RTC operation |
Reverse current warning & neutral loose or disconnect warning |
EVENT LOGGING |
|
Capacity of up to 255 events. All events are date & time stamped. |
|
User configuration of which event to log |
|
Operational Events |
Meter can record 200 programming events including parameter changes. |
Tamper |
Terminal cover open (time last 8 events) |
Quality of supply (QOS) Records the cumulative count & time as well as the fail & restore times of the last 7 events. In addition the values of all voltages (Pi), currents (Ii) & power factor at occurrence & restore time for each of the following QOS faults are logged: |
|
Phase failure |
Condition: Pi<20V for all i |
Phase Voltage loss |
Condition: Pi<70%Un & Ii>2%In |
Phase Current loss (open CT) |
Condition: Ii<2%In |
Voltage Imbalance |
Condition: If (Pi-Pj)/Ij>10% for any i≠j. |
Current Imbalance |
Condition: If Ii>5%for any I and (Ii-Ij)/Ij>30% for any i≠j. |
BILLING METERING |
|
Active energy (kWh) |
Import & Export |
Reactive energy (kVarh) |
Import & Export |
Maximum demand modes |
Block and Sliding / Rolling mode |
Demand cycles |
5,10,15,30 or 60 minutes |
Rolling interval |
2,3, or 5 minutes |
Registration |
Button set, or auto RTC |
Automated registering & history |
Last 16 and present period of energy & maximum demand for 4 tariffs |
Full Time of use (TOU) & Source of supply (SOS) |
Flexible control of the billing quantities for TOU and SOS |
INSTRUMENTATION METERING |
|
Harmonic values |
Optional (RS485) |
Phase angles |
Output (RS485) |
Instrumentation values via optical port, RS485 or LCD |
Voltage, Current & power factor per phase |
Power values (per sec) can be read via optical or RS485 |
Active (kWh), Reactive (kVArh), Apparent (kVA) |
TIME OF USE (TOU) CONTROL |
Switching by internal real time clock |
4 seasons, configurable |
10 daily time sections each selecting 4 tariffs |
24 public holidays per year, 100 special days |
Two different weekend days |
DATA LOGGING |
6 data logging channels can log any of 32 metered values (differential or cumulative) at 1 to 60 minute intervals. |
kWh (import, export, ABS), kVARh (import, export, ABS, Q1, Q2, Q3, Q4), kVA (import, export, ABS), kVAh (Q1, Q2, Q3, Q4), kVAr (import, export, ABS), kW (import, export, ABS), V (phase 1,2,3) A (phase 1,2,3) Power factor (phase 1,2,3, total) |
Non volatile flash memory |
Capacity of 2MB (4 channels logged every 20 min will record 900 days) |
MISCELLANEOUS OPTIONS |
Relay output |
Auxiliary voltage supply input to power meter |
2 Digital input signal connectors |
ACCESSORIES |
|
Optical Coupler for flag port with magnetic base (USB) |
|
PR510 programmer and reader used with MPS software |
|
EDAT+g for GSM/GPRS AMR at multi meter (128) installations |
|
EDAT+e for Internet AMR at multi meter (128) installations |
|
Meter Programming software MPS |
Meter reading & configuration software –download for free |
CASE AND DIMENSIONS |
|
Material |
Reinforced Clear Polycarbonate |
Dimensions |
263 x 175 x 83 mm |
Weight |
<1.5 kg |
Ingress rating |
IP60 |
Markings are in accordance with IEC1036 |
|
Property ownership marking (optional) |
|