ZAPp 3AM+
Download Brochure |
Download Manual
CONFIGURATION OPTIONS |
|
ZAPπ3AM240V5A4w |
3 phase, 4-wire, 240V, 5A, CT |
ZAPπ3AM240V100A4w |
3 phase, 4-wire, 240V, 100A, inline |
ZAPπ3AM240V160A4w |
3 phase, 4-wire, 240V, 160A, inline |
ELECTRICAL RATING |
||
Standards |
IEC62053-21, IEC62053-23 |
|
ZAPπ3AM240V Voltage Range (P-N / P-P) |
57.7/100 – 230 /400 V |
|
Frequency Range |
40 – 60 Hz |
|
Burden voltage circuit <1W, current circuit <0.05VA |
||
Operating temperatures |
-30 ºC to + 70 ºC |
|
Storage temperatures |
-45 ºC to + 85 ºC |
|
Accurancy Class 1 |
||
Protection Class 2 |
||
Supports CT connections |
||
Multipule meter can be installated (4 ZAPπ per set of CTs) |
||
DISPLAY |
Instrumentation values (see section) auto & keystroke scrolled |
Large 8-digit with backlight with icons for import, export, comms etc. |
IEC 62056-61 OBIS code display with digit height 11.9mm |
Life in excess of 15 years |
COMMUNICATIONS |
Standard IEC 62056-21 flag port |
Serial RS485 port |
INPUTS & OUTPUTS |
4 pulse outputs: Active import (kWh) export energy, Reactive import (kVAr) export energy |
Two energy verification outputs: Active (Wh) & Reactive (VArh) |
1 Hz pulse output |
Pulse output verification to IEC62053-31 standard |
RS485 |
LED outputs for active & reactive energy IEC62053-31 |
Push buttons for display and protected programming |
SECURITY (PHYSICAL & DATA) |
User access tracking: date & time and count |
Programming protection: sealed push button and password |
Factory sealed case. Sealable terminal cover by owner |
For power down a super capacitor, battery & backup battery ensures backup & continued RTC operation |
Reverse current warning & neutral loose or disconnect warning |
EVENT LOGGING |
|
Operational Events |
Last maximum demand reset & programming time |
Hardware Events |
Status for Battery Voltage, Memory, Meter Errors |
Tamper or supply failure |
Terminal cover open, per phase failure, power fail, power restore |
Quality of supply |
Voltage over & under record (user selectable thresholds) |
BILLING METERING |
|
Active energy (kWh) |
Import & Export |
Reactive energy (kVarh) |
Import & Export |
Maximum demand modes |
Block and Sliding / Rolling mode |
Demand cycles |
5, 10, 15, 30 or 60 minutes |
Rolling interval |
1, 2, 3 or 5 minutes |
Registration |
Button set, or auto RTC |
Automated registering & history |
Last 15 periods of energy & maximum demand for 4 tariffs |
Time of use (TOU) |
Flexible control of the billing quantities for TOU |
INSTRUMENTATION METERING |
|
LCD |
Voltage, Current & power factor per phase |
LCD |
Active (kW), Reactive (kVAr), Apparent (kVA) |
TIME OF USE (TOU) CONTROL |
Switching by internal real time clock |
4 seasons, configurable |
10 daily time sections each selecting 4 tariffs |
Public holidays & weekend days included |
PROFILE LOGGING |
2 data logging channels can log Average Active Power of demand cycle & Active Import Energy |
Non volatile flash memory |
Capacity: 20 min logging will record 165 days |
ACCESSORIES |
|
Optical Coupler for flag port with magnetic base (USB) |
|
PR510 programmer and reader used with MPS software |
|
EDAT+g for GSM/GPRS AMR at multi meter (128) installations |
|
EDAT+e for Internet AMR at multi meter (128) installations |
|
Meter Programming Software MPS |
Meter reading & configuration software –download for free |
CASE AND DIMENSIONS |
|
Material |
Reinforced Clear Polycarbonate |
Dimensions |
263 x 175 x 83 mm |
Weight |
<1.5 kg , depends on configuration |
Ingress rating |
IP60 |
Markings are in accordance with IEC1036 |
|
Property ownership marking (optional) |
|